survey
title-check us out

News & Events



SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL

 
 

SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL

with Reactive Power Control
The Sunny Mini Central 9000TL / 10000TL / 11000TL with Reactive Power Control are the solution when the electric power company is required to supply reactive power. The inverters can now be used to realize plant concepts which have specifications for the displacement factor cos φ and thus for the percentage of the reactive power. In this way, large-scale power systems, especially those in the megawatt range, can make optimal use of the distribution grid capacities provided. In doing so, they can significantly contribute to the success of renewable energy sources.


  Sunny Mini Central
9000TL
Sunny Mini Central
10000TL
Sunny Mini Central
11000TL
Input (DC)      
Max. DC power (@ cos φ=1) 9300 W 10350 W 11400 W
Max. input voltage 700 V 700 V 700 V
MPP voltage range / rated input voltage 333 V – 500 V / 350 V 333 V – 500 V / 350 V 333 V – 500 V / 350 V
Min. input voltage / initial input voltage 333 V / 400 V 333 V / 400 V 333 V / 400 V
Max. input current 28 A 31 A 34 A
Max. input current per string 28 A 31 A 34 A
Number of independent MPP inputs / strings per MPP input 1 / 5 1 / 5 1 / 5
       
Output (AC)      
Rated power (@230 V, 50 Hz) 9000 W 10000 W 11000 W
Max. apparent AC power 9000 VA 10000 VA 11000 VA
Nominal AC voltage / range 220 V, 230 V, 240 V / 180 V – 265 V 220 V, 230 V, 240 V / 180 V – 265 V 220 V, 230 V, 240 V / 180 V – 265 V
AC power frequency / range 50 Hz, 60 Hz / -6 Hz ... +5 Hz 50 Hz, 60 Hz / -6 Hz ... +5 Hz 50 Hz, 60 Hz / -6 Hz ... +5 Hz
Rated grid frequency / rated grid voltage 50 Hz / 230 V 50 Hz / 230 V 50 Hz / 230 V
Max. output current 40 A 44 A 48 A
Power factor at rated power 1 1 1
Adjustable displacement factor
Phase conductors / connection phases 1 / 1 1 / 1 1 / 1
Power balancing yes yes yes
       
Efficiency      
Max. efficiency / European efficiency 98 % / 97.6 % 98 % / 97.5 % 98 % / 97.5 %
       
Protection      
Reverse current protection / input-side disconnection device Optional (fuses) / yes Optional (fuses) / yes Optional (fuses) / yes
Ground fault monitoring / grid monitoring yes / yes yes / yes yes / yes
DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / — yes / yes / — yes / yes / —
All-pole sensitive residual current monitoring unit yes yes
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III I / III I / III
       
General Data      
Dimensions (W / H / D) 468 / 613 / 242 mm
(18.4 / 24.1 / 9.5 inch)
468 / 613 / 242 mm
(18.4 / 24.1 / 9.5 inch)
468 / 613 / 242 mm
(18.4 / 24.1 / 9.5 inch)
Weight 35 kg / 77.16 lb 35 kg / 77.16 lb 35 kg / 77.16 lb
Operating temperature range 25 °C ... +60 °C / -13 °F ... +140 °F -25 °C ... +60 °C / -13 °F ... +140 °F 25 °C ... +60 °C / -13 °F ... +140 °F
Noise emission (typical) 42 dB(A) 45 dB(A) 46 dB(A)
Self-consumption at night 0.25 W 0.25 W 0.25 W
Topology Transformerless Transformerless Transformerless
Cooling concept OptiCool OptiCool OptiCool
Degree of protection (according to IEC 60529) IP65 IP65 IP65
Degree of protection of connection area (according to IEC 60529) IP65 IP65 IP65
Climatic category (according to IEC 60721-3-4) 4K4H 4K4H 4K4H
Maximum permissible value for relative humidity (non-condensing) 100 % 100 % 100 %
       
Features      
DC terminal SUNCLIX SUNCLIX SUNCLIX
AC terminal Screw terminal Screw terminal Screw terminal
Display Text line Text line opt.
Interface: RS485 / Bluetooth opt. / opt. opt. / opt. opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt.
Certificates and approvals (more available on request) CE, VDE0126-1-1, DK 5940 ED2.2**, RD 1663/2000, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC-utility Meeting 216, IEC 61727, UTE C15712-1 CE, VDE0126-1-1, DK 5940 ED2.2**, RD 1663/2000, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC-utility Meeting 216, IEC 61727, UTE C15712-1 CE, VDE0126-1-1, DK 5940 ED2.2**, RD 1663/2000, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC-utility Meeting 216, IEC 61727, UTE C15712-1
* Does not apply to all national deviations of EN 50438
** Only applies to IT option
     
Data at nominal conditions      
Type designation SMC 9000TL-10 SMC 10000TL-10 SMC 11000TL-10
Home
    
About Us
    
Contact Us
    
Certifications
    
 
Products
All Products - Phoenix Contact
All Products - Phoenix Contact Automation
All Products - IDEC
All Products - AZBIL
All Products - HITACHI
All Products - SCHAFFNER
All Products - SIEMENS
All Products - RAYTEK
All Products - DANFOSS
All Products - MARECHAL ELECTRIC
All Products - SMA
All Products - ENTES
   
Featured Products
 
News & Events
 
Successful Project References
Tertiary Institution - Automation Lab
Waste Sewage Treatment in Petrochemical Industry
Wire Rope Testing for Marine Offshore Industry
Transportation System
   
Workshops
Phoenix Contact Automation Technology Workshop
IDEC PLC & Operator Interface Workshop
Siemens TIA Portal Programming Workshop
Testimonials
Photo Galleries
Need help? Call us at +65 6767 3232
or email us at This email address is being protected from spambots. You need JavaScript enabled to view it. 31 Mandai Estate #06-08 IMMEDIA @ Innovation Place Singapore 729933