IEC Inlet Filters / Power Entry Modules
IEC Inlet Filters / Power Entry Modules
All the advantages of IEC connector,EMC/EMI filter, fuses, switch and voltage selector combined in a powerful compact all-in-one solution. Ideal for computers, monitors, medical devices and office equipment like printers and copy machines.
IEC Inlet Filters
|
|
FN 9222 General performance IEC inlet filter
Excellent performance/size ratio Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type) Optional overvoltage protection (Z type)
Attenuation performance: standard Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 20 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
FN 9222E General performance IEC inlet filter with earth line choke
Excellent performance/size ratio Integrated earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Optional wide mounting flanges
Attenuation performance: standard Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 15 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
|
|
|
|
|
|
FN 9226 HF performance IEC inlet filter
Faston connection Optional PCB through hole connection Good HF coupling to the equipment housing Optional medical versions (B type)
Attenuation performance: standard Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 10 A Voltage: ≤ 250 V
|
|
|
|
FN 9233 High performance IEC inlet filter
Excellent attenuation performance Optional earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type)
Attenuation performance: standard,high Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 15 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
|
|
|
|
|
|
FN 9233E High performance IEC inlet filter with earth line choke
Excellent attenuation performance Integrated earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type)
Attenuation performance: high,very high Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 15 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
FN 9244 Excellent performance IEC inlet filter
Superior attenuation performance Optional earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type)
Attenuation performance: very high Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 15 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
|
|
|
|
|
|
FN 9244E Excellent performance IEC inlet filter with earth line choke
Superior attenuation performance Integrated earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type)
Attenuation performance: very high Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 15 A Voltage: ≤ 250 V Compliant IEC/EN 60601-1
|
|
|
|
FN 9246 High performance IEC inlet filter
Optional medical versions (B type)
Attenuation performance: high Frequency: dc to 400 Hz Leakage current: 373 to 797 µA Leakage current (B types): 2 µA Rated Current: 1 to 20 A Voltage: ≤ 250 V
|
Power Entry Modules with Fuses or Switch
|
|
FN 9260 General purpose power entry module with fuses
For one or two fuses Optional safety version (A type) Optional medical versions (B type) Snap-in versions (S type)
Attenuation performance: standard Frequency: dc to 400 Hz Leakage current: 373 µA Rated Current: 1 to 10 A Voltage: ≤ 250 V
|
|
|
|
FN 9263 General purpose power entry module with mains switch
1-pole rocker switch Snap-in versions (S and S1 type) Compact to fit 1U rack size
Attenuation performance: standard Frequency: 50 to 400 Hz Leakage current: 373 µA Rated Current: 1 to 10 A Voltage: ≤ 250 V
|
Power Entry Modules with Fuses or Voltage Selector
|
|
FN 280 Compact filtered power entry module
Single or dual-fuse holder Fuses Ø5 x 20mm 2-pole rocker switch General purpose application Optional earth line choke (E type) Optional medical versions (B type)
Attenuation performance: standard Frequency: 50 to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 1 to 10 A Voltage: ≤ 250 V
|
|
|
|
FN 370 Versatile filtered power entry module
Single or dual-fuse holder Fuses Ø6.3 x 32mm or Ø5 x 20mm Voltage selector 100/120/230/240V General purpose application Optional medical versions (B type)
Attenuation performance: standard Frequency: dc to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 2 to 6 A Voltage: ≤ 250 V
|
|
|
|
|
|
|
|
|
|
FN 380 Versatile filtered power entry module
Single or dual-fuse holder Fuses Ø6.3 x 32mm Ø5 x 20mm 2-pole rocker switch General purpose application Optional medical versions (B type)
Attenuation performance: standard Frequency: 50 to 400 Hz Leakage current: 373 µA Leakage current (B types): 2 µA Rated Current: 2 to 6 A Voltage: ≤ 250 V
|
|
|
|
FN 390 Versatile filtered power entry module
For one or two fuses Fuses Ø6.3 x 32mm or Ø5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke (E type)
Attenuation performance: high Frequency: 50 to 400 Hz Leakage current: 560 to 797 µA Rated Current: 1 to 10 A Voltage: ≤ 250 V
|