INTERFACE Safety | Safety relays, speed monitors and configurable safety modules

 

The safety relays from Phoenix Contact currently provide the highest safety standard for emergency stop and safety door circuits, as well as two-handed control systems

- PSR-TRISAFE configurable safety module
- PSR safety relays
- Downtime and speed monitors


PSR-TRISAFE configurable safety module
   
PSR safety relays
 

PSR-TRISAFE configurable safety module

As flexible as a control system and as simple as safety relay, the configurable safety moduleoffers you many advantages. The safety module evaluates individual safety devices such as emergency stop buttons or safety doors. The required safety functions can be freely configured using the SAFECONF software.
 
 
PSR-TRISAFE-S
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1,
SILCL 3 as per IEC 62061 SIL 3 acc. to IEC 61508
PSR-SAFECONF-BOX
PSR configuration package
   
Modular safety relay system for emergency stop, safety door, light grid and magnetic switch monitoring
 
 
 
 
 
   
PSR-SDC4
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-URM4/B
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-URD3/3
Safety category 3 as per EN954-1 Release delay time 0.3-3 s PL d as per ISO 13849-1 SILCL 2 as per IEC 62061
   
 
 
 
 
 
   
PSR-URD3/30
Safety category 3 as per EN954-1 Release delay time 0.5-30 s PL d as per ISO 13849-1 SILCL 2 as per IEC 62061
  PSR-SCP-URD3/T2
Safety category 3 as per EN954-1 Release delay time fixed 2 s PL d as per ISO 13849-1 SILCL 2 as per IEC 62061
  PSR-SIM4    
 
 
 
 
 
   
PSR-TBUS   PSR-TBUS-TP   PSR-SACB...PUR-SD
Sensor box, with connected master cable, with LED
   
             

PSR safety relays

Modular safety relay system for emergency stop and protective door circuits
 
 
 
 
 
 
 
PSR-ES...4
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-ES...4/B
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-ESA2/B
Safety category 4 as per EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-ESAM4
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
 
 
 
 
 
   
PSR-ESAM4/3X1
Safety category 2 as per EN 954-1 SIL 3 acc. to IEC 61508 PL d as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-ESP4
Safety category 2 as per EN 954-1 SIL 3 acc. to IEC 61508 PL d as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-FSP
SIL 3 acc. to IEC 61508
   
 
 
 
 
 
 
 
PSR-ESD-30
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061 Release delay time 0.1-30s
  PSR-ESD-300
Safety category 3/4 as per EN 954-1 PL d/e as per ISO 13849-1, SILCL 3 as per IEC 62061 Release delay time 0.2-300s
  PSR-ESD-T
Safety category 3/4 as per EN 954-1 PL d/e as per ISO 13849-1, SILCL 3 as per IEC 62061 Release delay time fixed
With screw connection
  PSR-ESD-T
Safety category 3/4 as per EN 954-1 PL d/e as per ISO 13849-1, SILCL 3 as per IEC 62061 Release delay time fixed
With spring-cage connection
 
 
 
       
PSR-URM4/B
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
  PSR-THC4
Requirements in acc. with EN 574 type IIIC Scnchronous activation input 1/2 <0.5s 
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061
       
 
 
 
       
PSR-URM4
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061 SIL 3 acc. to IEC 61508
  PSR-URM4_B
Safety category 4 in acc. with EN 954-1 PL e as per ISO 13849-1, SILCL 3 as per IEC 62061 SIL 3 acc. to IEC 61508
       
             
Positively driven coupling relays
 
           
PSR-URM            

Downtime and speed monitors

It is often essential to work with the safety door open when setting up a machine or a system. As such, the movements of the drives must be monitored for safe hold of safely reduced speed. If the speed of a drive exceeds the permissible maximum value, the system is switched off.
 
 
PSR-RSM4
Safety category 4 in acc. with EN 954-1 SIL 3 in acc. to IEC 61508
PSR-SSM
Safety category 4 in acc. with EN 954-1 SIL 3 in acc. to IEC 61508
Home
    
About Us
    
Contact Us
    
Certifications
    
 
Products
All Products - Phoenix Contact
All Products - Phoenix Contact Automation
All Products - IDEC
All Products - AZBIL
All Products - HITACHI
All Products - SCHAFFNER
All Products - SIEMENS
All Products - RAYTEK
All Products - DANFOSS
All Products - MARECHAL ELECTRIC
All Products - SMA
All Products - ENTES
   
Featured Products
 
News & Events
 
Successful Project References
Tertiary Institution - Automation Lab
Waste Sewage Treatment in Petrochemical Industry
Wire Rope Testing for Marine Offshore Industry
Transportation System
   
Workshops
Phoenix Contact Automation Technology Workshop
IDEC PLC & Operator Interface Workshop
Siemens TIA Portal Programming Workshop
Testimonials
Photo Galleries
Need help? Call us at +65 6767 3232
or email us at This email address is being protected from spambots. You need JavaScript enabled to view it. 31 Mandai Estate #06-08 IMMEDIA @ Innovation Place Singapore 729933